Vecotworks Spotlight recognises the following load cases and StageDocs assigns the Spotlight objects to the same load cases:
We assign the following partial safety factors to these load cases in accordance with EN 17879:
Load Case | Type | Faktor () |
---|---|---|
Light | Variable | 1,5 |
Video | Variable | 1,5 |
Audio | Variable | 1,5 |
Decoration | Variable | 1,5 |
Truss | Permanent | 1,35 |
Rigging | Variable | 1,5 |
Cable | Variable | 1,5 |
EN 17879 expects this categorisation of entertainment technology as a standard case, but allows deviations under strict requirements. StageDocs is a tool for operators. Therefore, this default setting cannot be changed.
Shortcut | Description | Formula |
---|---|---|
CHR | (characteristic) Characteristic service loads. All loads were recognised as actual loads. In other words, all loads were multiplied by a factor of 1.0 | |
STR | (structural) Design loads. All loads were calculated using the standard safety factors () and, if applicable, the lifting factor (). | |
DYN | (dynamic) All loads were multiplied by the lifting factor |