Various checks are performed during the calculation or export of a framework. These help to ensure that the system is created without errors. The messages generated during this process can range from simple hints about potential errors to serious errors that make the system uncalculable.
The following error types are created:
Type | Description |
---|---|
Overload | An overload was detected during component dimensioning. |
Error | The system cannot be calculated or the calculation contains serious errors. The system must be corrected. |
Warning | The system can be calculated, but there is a potential serious source of error. |
Information | The system can be calculated. There is no error if the settings are correct or intentional. |
The following table lists common errors and provides tips on how to fix them.
Error | Description / Proposed solutions |
---|---|
Calculation not possible | This error message means that the calculation has been cancelled because there are serious errors. Check the error messages and correct the errors. |
Overload | Overloads occur when the system is overloaded at one point. This can happen if the loads or spans of a system are actually too high. However, it can also happen if the system has geometric errors. For example, if a chain hoist is not correctly connected to a system, or if supports are missing. |